When you are searching for top-quality products sold under the NSN 5945-01-470-1862, we have you covered. This particular item is listed alongside the NSN part number H3M AC120 B, BRL011. When you send us a completed request, a member of our staff will quickly formulate a solution that keeps your needs and restrictions in mind before presenting it to you in 15 minutes or less. As NSN parts under this NSN 5945-01-470-1862 is ready for purchase from our website at any time, do not hesitate to request a quote for your comparisons using our online RFQ forms. As we have team members readily available around the clock for customer needs, you may also always give us a call or email to directly reach out to us. With our dedication to customer satisfaction and part quality, we proudly carry out operations with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. See how we can serve you today when you get in contact with one of our representatives.
Item Name | Relay Electromagnet |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 01-470-1862 (014701862) |
NCB Code | USA (01) |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
H3M AC120 B | omron electronics ltd | relay electromagnet | Avl | RFQ |
BRL011 | general dynamics satcom technologies | relay electromagnet | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | Overall Length | 50.0 MILLIMETERS NOMINAL |
AXHR | Mounting Facility Type And Quantity | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
ABMK | Overall Width | 40.0 MILLIMETERS NOMINAL |
ABKW | Overall Height | 81.6 MILLIMETERS NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
CSXF | Operating Voltage Rating And Type At Specified Temp | 120.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS |
TTQY | Terminal Type And Quantity | 8 STANDARD TUBE BASE ALL FUNCTIONS |
CWAB | Main Contact Maximum Voltage Rating In Volts | 250.0 AC |
AJSS | Frequency In Hertz | 50.0 MINIMUM AND 60.0 MAXIMUM |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 3.0 AMPERES AC RESISTIVE LOAD |
FEAT | Special Features | THIS SOLID-STATE TIMER RELAY CAN BE SET TO TIME RANGES OF 0.1 TO 1.0 SECONDS, 1.0 TO 10.0 SECONDS, 0.1 TO 1.0 MINUTES, AND 1.0 TO 10.0 MINUTES BY CHANGING ONE OF FOUR WHITE MULTIPLIER KEYS; TIME LIMIT CONTACT IS DPDT; OPERATING VOLTAGE IS 85 TO 110 PERCENT OF 120 VAC; POWER CONSUMPTION IS 2 VA NOMINAL; INSULATION RESISTANCE IS 100 MEGOHMS; WITHSTANDS DIELECTRIC STRENGTH OF 2000 VAC; VIBRATION AND SHOCK RESISTANT; AMBIENT OPERATING TEMPERATURE IS MINUS 10 TO PLUS 50 DEG. C; AMBIENT STORAGE TEMPERATURE IS MINUS 25 TO PLUS 80 DEG. C; RELATIVE HUMIDITY 45 TO 85 PERCENT; HAS POWER ON AND TIME-UP INDICATORS; STANDARD SURFACE MOUNT CAN BE FLUSH MOUNTED USING ADAPTOR P/N Y92F-40, CAGE 61964 |
APNP | Duty Type | CONTINUOUS |
5998-01-190-8313 (5998011908313) | 5998-01-082-6319 (5998010826319) | 5935-00-712-3818 (5935007123818) | 5935-01-509-4579 (5935015094579) |
5960-00-752-5605 (5960007525605) | 5945-01-621-8665 (5945016218665) | 5935-01-129-4151 (5935011294151) | 5930-01-167-8419 (5930011678419) |
5905-00-106-2682 (5905001062682) | 5905-00-088-1026 (5905000881026) | 5962-01-609-5832 (5962016095832) | 5998-01-430-2289 (5998014302289) |
Warrantied inventory at competitive
prices
Search the world’s largest inventory of electronic components by manufacturer, category or part number
We sell only warrantied and
traceable parts
All inventory ready to ship from our
sellers
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote